The Role and Importance of VPD in Cannabis Cultivation

Did you like this article?

Temperature and humidity: these are the first two numbers every grower keeps an eye on. But taken separately, they don’t tell us much about how a cannabis plant grown from the highest-quality feminized seeds. A humidity level of 60% does not have the same effect at 20°C as it does at 28°C.

This is where the VPD comes into play, to vapor pressure deficit in English, or “déficit de pression de vapeur” if you prefer. Long reserved for professional greenhouses, this indicator has become a benchmark for discerning growers, as it combines temperature and humidity into a single value directly linked to the plant’s functioning. Understanding it well means better control over growth, flowering, and the health of your plants—as well as the quality of your harvest.

What is VPD?

VPD measures the difference between the amount of water vapor that air could hold at a given temperature if it were saturated and the amount it actually contains. It is expressed in kilopascals (kPa).

Simply put, it indicates the air’s “thirst”—or rather, the lack or excess of water in the air—which interacts directly with a specific temperature to ensure that plants grow optimally. The higher the VPD, the drier the air is and the more moisture it draws from the leaves. The lower it is, the closer the air is to saturation, and the less the plant transpires.

The calculation is based on two factors:

  • Saturation vapor pressure, which depends solely on temperature: the warmer the air, the more water it can hold.
  • Relative humidity, which indicates what percentage of that maximum is actually present.

The simplified formula is: VPD = saturated vapor pressure × (1 − relative humidity / 100). For example, at 25 °C, the saturated vapor pressure is approximately 3.17 kPa. With 60% humidity, the VPD of the air is therefore approximately 3.17 × 0.4, or 1.27 kPa.

To be even more precise, experienced growers use leaf temperature rather than air temperature, measured with an infrared thermometer. Leaves are often slightly cooler than the ambient air, which slightly lowers the actual VPD. Under certain intense lighting conditions (HPS), however, they may actually be warmer.

Read this article : Future Of Grow (F.O.G): Swiss LED lights that are redefining indoor cultivation

Why VPD Is So Important

VPD directly affects transpiration, the process that circulates water and nutrients throughout the plant. When water evaporates through the stomata—the tiny pores on the underside of the leaves—it creates a suction that draws sap up from the roots.

A VPD that is too low (air that is too humid). The plant transpires very little. Sap flow slows down, as does nutrient absorption—particularly that of calcium, which is heavily dependent on water flow. Most importantly, moisture lingers around the leaves and flowers, creating the ideal environment for pathogenic fungi such as powdery mildew and Botrytis, the dreaded gray mold that affects flower heads.

A VPD that is too high (air that is too dry). The plant loses water faster than it can absorb it. To protect itself, it closes its stomata, which also slows down CO₂ uptake and, consequently, photosynthesis. The result: slowed growth, curled leaves, scorched tips, and sometimes a buildup of salts in the growing medium.

A properly regulated VPD. The plant transpires at a steady rate, efficiently absorbs water and nutrients, and is less susceptible to disease. The dryback process is thus well-regulated both mechanically and biologically. This is essential for vigorous growth and a flowering period that will yield thick, compact buds with a fragrant, intense, and complex aromatic profile.

Detailed Operating Principle of the VPD

VPD Values by Stage

The ideal VPD gradually increases as the crop grows: low for fragile young plants, and higher during flowering to protect the flowers from moisture.

StadiumIndicative VPDWhy
Seeds and Cuttings0.4 to 0.8 kPaPoorly developed roots: Limit transpiration
Growth0.8 to 1.2 kPaThe plant may transpire more and grow quickly
Early and mid-bloom1.0 to 1.5 kPaGood balance between moisture absorption and mold prevention
End of flowering1.2 to 1.6 kPaDrier air to protect dense flower clusters from botrytis

These ranges are guidelines commonly used in indoor cultivation by most experienced growers, but they are not absolute rules. They vary depending on whether the cannabis strains are feminized or not, lighting, the growing medium, and each grower’s experience. The key is to stay within the viable (green) zone and avoid sudden changes. First and foremost, it’s essential to fully understand the inertia of the variable environmental parameters specific to your growing setup.

Read this article : Mistakes to Avoid When Growing CBD Seeds: How to Grow Successfully and Maximize Your Results

Table of VPD by Temperature and Humidity

This table lists the VPD of the air, in kPa, for the most common combinations used in indoor cultivation. It allows you to quickly identify the correct temperature-humidity combination for each stage.

Temperature70% RH65% RH60% RH55% RH50% RH40% RH
20 °C0,700,820,941,051,171,40
22 °C0,790,931,061,191,321,59
24 °C0,901,041,191,341,491,79
26 °C1,011,181,341,511,682,02
28 °C1,131,321,511,701,892,27
30 °C1,271,491,701,912,122,55

Here are a few examples: at 24 °C and 65% humidity, a VPD of about 1.0 kPa is ideal for growth. At 26 °C and 50% humidity, the VPD reaches about 1.7 kPa—a value that is already high and may cause stress to the plant, even at the end of the flowering stage.

These values are calculated based on the air temperature. If your leaves are cooler than the ambient air, the actual VPD will be slightly lower.

How to Adjust Your VPD

It all starts with reliable measurements: a high-quality thermo-hygrometer, placed at canopy height and shielded from direct light. A model that records minimum and maximum data allows you to track changes both day and night. It’s important to closely monitor these values throughout the entire growing cycle. To take things a step further, an infrared thermometer measures leaf temperature; it may be worth purchasing one for more precise monitoring.

To lower the VPD (air that is too dry):

  • increase humidity with a humidifier;
  • lower the temperature slightly;
  • reduce excessive air extraction that dries out the space;
  • Avoid having light or a fan blow directly on the plants.
Read this article : Mary Jane Berlin 2026: A Pivotal Event That Confirms Germany's Dominance in the European Cannabis Industry

To increase the VPD (air that is too humid):

  • Use a dehumidifier, which is essential during the flowering stage for most indoor crops;
  • raise the temperature slightly;
  • increase air extraction and circulation throughout all areas of the growing space;
  • Avoid overwatering and standing water in the saucers.

Consider the difference between day and night. When the lights go out, the temperature drops and humidity often rises, causing the dew point to plummet. This is when the risk of mold is highest. A dehumidifier that runs overnight and a moderate temperature difference between day and night help limit this phenomenon.

Adjust gradually. It's better to make small adjustments over several days than to make drastic changes that stress the plant.

Explanatory diagram of the vapor pressure deficit

Mistakes to Avoid

  • Don't just look at humidity alone. The same humidity level can be perfect at 22 °C but much too dry at 28 °C. It is precisely the combination of these two parameters that must be taken into account.
  • Placing the sensor in the wrong spot. A hygrometer placed on the floor, near a wall, or under a light will give inaccurate readings. Place it at the level of the plants for a more accurate reading.
  • Don't forget about nighttime. A perfect VPD during the day can drop to dangerously low levels after dark, especially toward the end of the flowering period.
  • Chasing an exact value. The VPD is a guideline, not an obsession. A healthy plant within the correct range is better than constantly adjusting settings that keep stressing it out.
  • Ignoring the plant's signals. Curled leaves, scorched tips, slow growth, or the appearance of mold: these symptoms often reveal more than the numbers do.
  • Neglecting air circulation. Even with a good VPD, stagnant air creates humid microclimates, such as pockets of air around the flowers. That’s why it’s a good idea to place thermo-hygrometers in different locations throughout your cannabis grow, as well as at different heights—in addition to those placed near the canopy—to accurately monitor how values vary across the different air layers in your space and ultimately verify the consistency of your overall climate. This is the key to climate control, which helps prevent the vast majority of problems.

Conclusion

The VPD converts two familiar measurements—temperature and humidity—into an indicator directly linked to how the plant breathes, drinks, and feeds. When properly adjusted, it promotes vigorous growth, better nutrient absorption, and flowers that are better protected against mold.

That doesn’t mean you need to obsess over it, though. A good thermometer-hygrometer, the reference chart above, and a little observation are all you need to keep your plants in the right range, from seedling to harvest.

Reminder: Growing cannabis that contains THC is prohibited in France and in many other countries. This article is provided for informational purposes only; please check the laws in effect where you live.

Share on Facebook
Share on Twitter
Share on LinkedIn
Share on Pinterest